PRODUCT DESCRIPTION
ADVANCED SENSOR PIPE SECTION MULTIPHASE FLOW CONE SEAL MF ELECTROMAGNETIC FLOWMETER
The flow measurement range is wide, and the range ratio is 1500:1.
The flow rate of minimum guaranteed accuracy is 0.2m/s.
Advanced sensor technology can ensure that the installation of straight pipe section takes only 1.6D.
High accuracy: up to 0.2% indicating value
Forward and backward flow are measurable: pulse flow, multiphase flow and slurry are measurable.
The input of the converter is more than 1012 ohms, which can effectively prevent the influence of scaling on the sensor, and the minimum conductivity can reach 1.7us/cm.
The electrode seal adopts a unique double-sided sealing method of cone seal and line seal.
Buried installation and long-term immersion installation are allowable, up to IP68.
Multi-frequency excitation technology/DSP digital processing technology/high frequency sampling technology/data coordinating analysis technology
Self-diagnosis (excitation circuit/empty pipe detection/upper and lower limits/system storage)
Main Technical Parameters:
Flow Master
MFE-S type
High protection
electromagnetic flowmeter
split type
One type
(IP67)
Explosion proof integrated type
Basic error ± 0.2% or ± 0.5% of the indicated value
caliber (mm) DN2.5~DN2400 DN2.5~DN2400
Explosion proof grade ------------ Exia/de Ⅱ CT4 Ga/Gb
flange Comply with gb9119 standard, carbon steel (optional stainless steel)
Pressure class
DN2.5~DN600 1.0 1.6 2.5 4.0MPa
DN700~DN2400 0.6MPa
The special pressure shall be determined through consultation with the company
DN2.5~DN600 1.0 1.6 2.5 4.0MPa
The special pressure shall be determined through consultation with the company
Lining material PTFE polytetrafluoroethylene, polyurethane rubber, PFA, F46, natural rubber, neoprene, ETFE
conductivity ≥5μS/CM(Less than ≥ 5 μ S / cm negotiates the order with our company )
electrode 316L, Hastelloy, titanium, tantalum, platinum iridium alloy, tungsten carbide
Degree of protection IP67(Sensor optional IP68) IP67
Medium temperature
-25℃~140℃
See lining material selection for details
-25℃~80℃
See lining material selection for details
ambient temperature -25℃~60℃
Influence of ambient temperature <±0.1%/10℃or<±0.25%/10℃
Repeatability and repeatability ≤±0.1%or±0.25%
Analog output error ≤±0.02mA
Measuring range flow rate ≤20m/s
Embedability ≤5m(Only IP68) -----------
Sensor cable
<100m
If it is too long, you need to negotiate with our company to order
-----------
Electrical connection M20*1.5Sealing sleeve,G1/2,NPT1/2
Output interface* Standard output (pulse + 4 ~ 20mA single current output), dual current output, RS485,HART,Profibus-PA
Note*: 4-20mA analog output is active output
Product performance
·The simple measured current output is used to display the flow, and the pulse output is used to drive the external accumulator or as the status output
·Can ensure the reliability, safety and stability of measured values of all basic functions
·The optimized process control accuracy is + 0.5%
·PTFE lining ensures maximum corrosion resistance and temperature resistance up to 130 ℃
·It can be assembled under most difficult conditions (such as shaft, vibration or long-term underwater). The sensor can be installed independently without sensor, and the protection level is IP68
·The functional design makes maintenance simple and easy. Hart, fieldtool and fieldcheck provide support for equipment verification, so there is no need to move the sensor
Application Scenarios:
DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor 0
DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor 1
DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor 2
DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor 3
DSP Digital Electromagnetic Flow Meters , IP67 Water Pipe Flow Sensor 4