NACHI PRESSURE CONTROL VALVE
This circuit control valve works as a sequence valve, unloading valve, and counter balance valve.
Maximum operating pressure is 21MPa {214 kg f /cm2}.
Though a direct type valve, there is little pressure override.
NACHI (C) Q-T03-*A-21
NACHI (C) Q-T06-*A-21
NACHI (C) Q-T10-*A-21
NACHI (C) Q-G03-*A-21
NACHI (C) Q-G06-*A-21
NACHI (C) Q-G10-*A-21
Weight values in parentheses are for when a check valve is included. The cracking pressure of the
check valve is 0.1MPa {1.0kgf/cm2}.