1000kw 1250KVA Container type Industrial cummins silent diesel generator
PRODUCT DESCRIPTION
Cummins Engine :
Cummins is the world's leading manufacturer of power equipment. It has invested more than US$140
million in China. As the largest foreign investor in China's engine industry, Cummins has eight joint
ventures and wholly-owned manufacturing companies in China, of which Dongfeng Cummins produces
B. C and L series diesel engines, Chongqing Cummins produces M, N and K series diesel engines.
The products comply with ISO 3046, ISO 4001, ISO 8525, IEC 34-1, GB1105, GB/T 2820, CSH 22-2,
VDE 0530 and YD/T 502-2000 "Technical requirements for communication-specific diesel generator sets"
and other standards.
1000 Kw Cummins Diesel Generator , Diesel Electric Generator Container Type 0
Genset Model BS-C1250
Prime Power (kw/kva) 1000/1250 Standby Power(kw/kva) 1100/1375
Voltage (v) 400/230 Rated Speed (rpm) 1500
Frequency (Hz) 50 Rated Current (A) 1804
Connection: 3 phase 4 wire Power Factor: 0.8
Engine Model: KTA50-G3 Alternator Model: LVI 634G
Net Weight (kgs)-Open 11000 Net Weight (kgs)-Silent 13000
Dimensions (mm)-Open 4980X2070X2300 Dimensions (mm)-Silent 40’Ft container
Engine Parameter:
Manufacturer/Model
Air Intake System
Fuel System
Cylinder numbers
Displacement
Bore x Stroke
Compression Ratio
Max. Power
Governing System
CCEC, Cummins, KTA50-G3, 4 stroke
Turbocharged, Air/-water Cooled
PT Fuel Pump, EFC electronic governor
60° Vee,16 cylinders
50.3L
159 x 159 mm
13.9 : 1
1227KW / 1669HP
Electronic
Exhaust System
Exhaust gas flow
Exhaust temperature
Max. Back Pressure(mm Hg)
3728 L/s
520 ℃
51
Intake System
Max. Allowed Pressure
with Dirty Filter Element (mm H 2 O)
with Clean Filter Element (mm H 2 O)
Air Flow
635
381
1605 L/s
Fuel System
100% Load (Prime)
75% Load(Prime)
50% Load (Prime)
261L/h
199L/h
139L/h
Lube System
Oil Capacity
Total system capacity(L)
Oil Pressure at rated speed
151 L
177 L
345-483 kPa
Cooling system
Coolant Capacity(Engine only)
Thermostat
Max. Water Temperature
161 L
82-93℃
104℃
Alternator Parameter: Basic Information
The alternators meet the standards of:
GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350
Technical Data:
Manufacturer:
Phases:
Connection:
Bearing numbers:
Power Factor:
Protection Class:
Altitude Condition:
Excitation:
Insulation class/Temp. rise class:
Tel. Influence Factor TIF:
Tel. Harmonic Factor THF:
Steady State Voltage Regulation:
Alternator Capacity:
Efficiency:
Cooling Air Flow:
STAMFORD,LVI 634G
3
3 phase 4 wire, Y type
1
0.8
IP23
≤1000M
Brushless, self-excitation
H / H
<50
<2%
≤±1%
1250KVA
94.9%
2.69m³/s
Engine
Heavy duty diesel engine
Four stroke , water cooled
12V and 24V stater and charge alternator
Cooling radiator and fan
Maintenance free battery including ract and cable
Flexible fuel connection hoses and manual oil sump drain valve
Exhaust silencer
Alternator
Brushless , single bearing , flexible disc
Insulation class : H
Protection class : IP23
Self-exciting and Self-regulation
FAQ
Q : Do you offer OEM service?
A : Yes
Q : What is your payment term?
A : 30% T/T in advance, the rest payment before shipment. Or irrevocable L/C.
Q : What is your lead time?
A : About 30 days after receiving deposit or original L/C.But if your order with some special design,
then the delivery time is longer.
Q . How to choose the power ?
A : Collect all power of your equipments , take the current into your consideration .
Q . What is the difference between Prime power and Standby power ?
A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited