50Hz 18KW Frecon Solar Pump Inverter Single Phase Water Pump IP20

Product Introduction In response to a high torque and speed control For fast start-stop, suddenly loading and unloading of the occasion Mutation load, the torque limiter function of mechanical protection Pearl wave restriction function Can effectively prevent an overcurrent warning or interferen...
Product Introduction



In response to a high torque and speed control
For fast start-stop, suddenly loading and unloading of the occasion
Mutation load, the torque limiter function of mechanical protection
Pearl wave restriction function
Can effectively prevent an overcurrent warning or interference caused by a sudden load, thereby protecting the safety device.
Tracking speed smooth start
Rich fault protection and operation monitoring function
Diverse control
Excellent current control ability, to ensure that the rapid acceleration process does not trip operation, and the acceleration time is shorter
Powerful overload suppression ability to ensure that the inverter will not stop due to overload faults at the maximum output;




Solutions


1. Inverter automatically working

When the input DC voltage lower than 230V, the inverter will turn to dormancy.
It will automatically wake up and working once input DC voltage higher than 230V.

2. Dry-run function with three solutions

1) Dry-run function without sensor.
2) Analog sensor detect Water function.




Solar Panel Configure

In the case of not exceeding the maximum input voltage, the greater the power the better, the greater the voltage the better.

① Configure Solar panel power: 1.3 times of Pump’s power.

② Arranged solar panel voltage: 220V inverter board recommended Voc 360 ~ 430VDC, 380V inverter board recommended Voc 600 ~ 750VDC.

③ Solar panel output current: solar panel’s Imp> Motor rated current



Input specication
Model PV150-2S PV150-4T
PV500-4T
Maximum Input DC Voltage 450VDC 800VDC
Re commended Voc Range 360~430VDC 600~750VDC
Re commended MPPT Voltage Range 250~350VDC 450~600VDC
Starting Voltage Range PV150:80~450VDC 230~800VDC
Grid or backup generator input
Input voltage 2S: Single phase 220V(-15%~20%) Three phase 380V(-15%~30%)
Output specication
Rated output voltage 3PH 220V 3PH 380V
Output frequency 0~600.00Hz (default: 0~50.00Hz) 0~600.00Hz (default: 0~50.00Hz)
Protection
Built-in Protection Lighting Protection, over-current,overvoltage,output phease-lose,under-load, under-voltage,short circuit, overheating, water pump run dry etc. Lighting Protection, over-current,overvoltage,output phease-lose,under-load, under-voltage,short circuit, overheating, water pump run dry etc.
General Parameters
Application Site No direct sunshine, no dust,cirrisuve gas, combustible gas, oil mist, steam, dripping or salinity etc.
Altitude 0~2000m Derated use above 1000m, per 100m, the rated outed output currentdecrease 1%
Environment Temperature -10°C~40°C (Environment Tenmperature be 40°C~50°C, please keep derated use.)
Humidity 5~95% non-condensation
Vibration less than 5.9 m/s² (0.6g)
Storage Temperature -20°C~+70°C
Effciency Rated Power Run ≥93%
Installation Wall or rail mounting
Protection Grade IP20
Cooling Forced Air Cooling

Associated Products